Can a heat pump keep up with winter here
Your winters make the case for a furnace before cost even comes into it. The average overnight low from December through February is 14°F, and a standard heat pump starts losing ground at two points well above that. Below 40°F it already puts out less heat than its rating says. Below about 35°F it usually needs backup heat to make up the difference. Your average winter night is under both marks, and every single one of the roughly 200 nights a year that drop to freezing or below is under both marks too.
That doesn't rule out a heat pump. It means a standard one spends most of the winter leaning on backup heat, usually electric resistance, which costs more to run than the heat pump itself. A cold climate model is built for this. To earn that label a heat pump has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its rated capacity at that temperature, tested by a third party rather than claimed by the manufacturer. Field tests of prototype cold climate units back this up: backup heat covered only a small share of the load between 0°F and 35°F, and the unit running on backup alone was rare even above 0°F. About 20 nights a year here reach 0°F or below, under a quarter of your freezing nights. A furnace does not have any of these thresholds to worry about. It makes the same heat on a 14°F night as a 40°F one.