Before you call anyone, check the thermostat batteries and make sure it's set to the right mode and a temperature that should call for heat or cool. Go outside and look at the outdoor unit. If it's covered in ice or snow, that can block airflow and stop it from working right, though a heat pump defrosting itself now and then is normal. Check that nothing is blocking the outdoor unit, no branches, no stacked snow, nothing sitting against it. Inside, pull the air filter and hold it up to a light. If you can't see through it, swap it or clean it, since a clogged filter chokes airflow and can make the whole system struggle. Last, check the breaker panel for a tripped breaker. If the outdoor unit is dead quiet and the breaker's fine, that points to something electrical that needs a trained eye.

14°F
the average winter night it heats against
73°F
the average summer afternoon it cools against
Isometric cutaway illustration of a single-story house showing interior rooms, ceiling ductwork, an indoor air handler, and an outdoor condenser unit connected by lines on the ground.

Montana electricity ran 12.66 cents per kilowatt-hour in 2024.

A heat pump that's struggling pulls more power just to limp along, and that shows up on your bill every month it runs that way.

White Sulphur Springs winters are cold and old homes are common. Neither one is why your heat pump is acting up.

Half the homes here were built by 1976
26 winter storms from 2015 to 2024
Winter nights average 14°F

If your heat pump is the reason your bill climbed, waiting doesn't help it. A system drawing extra power to make the same heat will keep doing that until someone finds why it's struggling, whether that's a failing part or a refrigerant charge that's off. Get it looked at soon instead of riding it out through the cold months. The longer it runs wrong, the more those months cost.

Stop paying for a struggling machine

Power costs more here, so a machine that's running badly costs you every month. Get it fixed soon.

Find a contractor
A man in a dark long-sleeved shirt and olive work pants carries a canvas tool bag up steps toward a blue-gray front door of a shingled house, with a potted shrub beside the entry.
A dark gray heat pump unit mounted on a concrete pad next to a house with gray siding and a stone veneer wall.

What a tech actually checks

A diagnostic starts outside, at the outdoor unit. The tech checks the reversing valve, since that's what switches the system between heat and cool, and a stuck valve will leave you with one or the other, not both. They'll check refrigerant pressures, because a low charge means the system works harder to move the same heat and still falls short. Inside, they check the air handler, the blower motor, and the defrost control board, which decides when the outdoor coil needs to clear itself of frost. A board that's misreading things can leave the unit stuck in defrost, or never trigger it at all, so ice builds up and chokes airflow. They'll also test the capacitor that starts the compressor and the one that runs the fan, since a weak capacitor makes a motor strain to start or run, and that strain is often what's driving the power draw up before anything fully fails.

Frost does not stay put

A coil that is not clearing itself right will build ice a little more each cycle, and ice blocks the airflow the coil needs to pull heat from outside air. Once airflow drops, the system leans harder on backup heat to keep the house warm. Left alone, that coil can end up packed solid, and a solid coil takes a lot longer to thaw and fix than it would have taken to catch when the frost was thin.

A motor under strain wears from the inside

A compressor or fan motor fighting a weak capacitor pulls more current every time it starts. That current shows up as heat inside the motor, and heat breaks down windings that were fine a month ago. None of that reverses itself by running more. A capacitor is a small part to replace. The motor it was feeding is not.

Most heat pump failures trace back to a handful of parts, and they tend to go in the same order. Capacitors go first, since they're cycling every time the system starts and stops, all year. A reversing valve comes next, usually from age or from sitting stuck in one position too long. Refrigerant leaks are slower, a slow weep at a fitting or coil that shows up as weaker heat over weeks, not all at once. The defrost board and sensor fail less often, but when they do, the outdoor coil stops clearing itself and ice takes over from there. Compressors rarely fail on their own. Almost always something smaller failed first and the compressor just inherited the strain.

A heat pump works in both directions, so there's more that can go wrong than on a furnace, but that also means more of what fails is a smaller part doing a specific job rather than the compressor itself. If the compressor is sound, most failures are a capacitor, a contactor, a sensor, parts worth fixing no matter how old the system is. What changes the call is a compressor that's failing, or a coil leaking in more than one spot, since those sit at the center of the system and everything else depends on them. Age matters less than how the unit has been run. A heat pump that's been short on refrigerant for a long stretch, or leaning on backup heat more than it should, has likely been straining parts that would otherwise hold up fine. A tech finding one worn part on a system that's otherwise been kept up with, that's a repair. A tech finding a second or third failure in a short stretch, that pattern is telling you something the next repair won't fix.