What the cold here does to a heat pump
Winter nights in Sheridan County average 4°F. A standard heat pump starts falling short of its rated heat once it's below 40°F outside, and by the time it's in the teens it is putting out only a fraction of that rating. Below about 35°F it usually needs backup heat to make up the rest. Every one of the roughly 200 nights a year here that drop to freezing or below falls under both of those marks.
That backup heat matters because of how often it would run here. About 200 nights a year here hit 32°F or colder, over half the nights in the ten months the heat runs. About 45 of those reach 0°F or colder. A standard heat pump built to the federal minimum is not built for that. It is built for a climate where cold snaps are the exception.
There is a version built for this. The ENERGY STAR Cold Climate heat pump has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that same temperature, checked by outside testing, not the manufacturer. In a two-winter field test of prototype cold-climate units in occupied homes, backup heat covered only a small share of the load between 0°F and 35°F, and the unit running on backup alone was rare even above 0°F.
A gas furnace does not have this problem to begin with. It makes the same heat at 4°F that it makes at 40°F. If a heat pump is on the table for this house, the question is not whether it can work here. It is whether it's the cold-climate kind, because a standard one and a cold-climate one behave very differently on your coldest nights.