What the cold actually does to a heat pump here
Winter in Missoula County is the whole question. The heat runs ten months a year, September through June, and the overnight low averages 17°F in December, January and February. That's not an occasional cold snap. About 170 nights a year here drop to freezing or below, more than half the nights the heat is even running.
A standard heat pump starts losing ground well before it gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it typically needs backup heat to make up the difference. Missoula's average winter low of 17°F is past both of those marks, and every single one of those 170 freezing nights is too. This is not a system that deals with the cold once in a while here. It deals with it most of the winter.
The nights that reach 0°F or below, about 7 a year, are the smallest part of the problem. A cold-climate heat pump with the ENERGY STAR rating is built to handle that end of things, holding most of its capacity and efficiency even at 5°F. Field tests of cold-climate models back this up: backup heat covered only a small share of the load between 0°F and 35°F, and the system running on backup alone was rare above 0°F. So if a heat pump is going in here, the cold-climate version is the one that holds up, and the plain standard model is the one that struggles through most of the season.