Winters here are long and cold, and that decides it
Heat runs about ten months a year in Cascade County, September through June. That is almost the whole calendar, and it is the number to weigh everything else against. Cooling only matters in July.
The average overnight low from December through February is 16°F. About 150 nights a year dip to freezing or below, roughly half the nights heat runs at all. About 19 of those nights hit 0°F or colder.
A standard heat pump starts falling short of its rated heat output once it is below 40°F outside, and by the teens it is putting out only a fraction of what it is rated for. It often needs backup heat below about 35°F too. The average winter night here, 16°F, is under both marks, and every single night at or below freezing is as well.
That does not rule out a heat pump. Cold climate models carry an ENERGY STAR rating that requires them to still make at least 1.75 units of heat for every unit of electricity at 5°F, and to hold on to 70 percent of their warm weather capacity at that temperature, checked by outside testing. A field test of prototype cold climate heat pumps over two winters found backup heat covered only a small share of the load between 0°F and 35°F, and that running on backup heat alone was rare even above 0°F. So the machine that struggles at 16°F is the standard one. A cold climate heat pump is built for exactly this kind of night.