Can a heat pump handle a Valley County winter
Your winter low here averages 6°F, and that's the number that decides this. A standard heat pump starts losing heating capacity below 40°F and often needs backup heat below about 35°F. Six degrees is below both marks, and so is every one of the roughly 180 nights a year here that drop to freezing or lower. This isn't a system that dips below its comfort zone a few nights a year. It spends more than half its working life there.
That doesn't mean a heat pump can't heat your house. It means it can't do it alone. Below 35°F it leans on backup heat, usually electric resistance coils, to make up the difference, and that backup heat is expensive to run. The cost figures above, $1.69 against $0.97 per 100,000 Btu, don't even include it. They're the heat pump's best case, running at its rated efficiency with nothing added for the coldest nights. Add the backup heat this climate actually demands and the real gap is wider than the numbers above show.
There's a real exception. An ENERGY STAR Cold Climate heat pump is tested and certified to keep at least 70 percent of its heating capacity at 5°F, and to make at least 1.75 units of heat for every unit of electricity it uses at that temperature. That's a different machine than the standard one the cost comparison above is built on. Field testing of cold-climate models in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. If a heat pump is going into this county, that's the kind worth asking for by name.