Winters here are long and genuinely cold
Glacier County doesn't get a shoulder season. Heat runs here in every month of the year. The overnight low averages 14°F across December, January and February, and it drops to freezing or below on about 190 nights a year, roughly half the nights there are. About 25 of those nights hit 0°F or colder.
A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F it already puts out less than its rated capacity. Below about 35°F it often needs backup heat to keep up. Here, the average winter low of 14°F is under both marks, and every single one of those 190 freezing nights is too. This is not a system that deals with the occasional cold snap. Cold is the normal condition it has to run in.
That doesn't rule out a heat pump. Cold climate models carry a separate rating for exactly this: to earn the ENERGY STAR Cold Climate mark, a heat pump has to keep making at least 1.75 units of heat per unit of electricity at 5°F, and hold onto at least 70 percent of its 47°F capacity at that same temperature, checked by outside testing. A field test of prototype cold climate units over two winters found backup heat covered only a small share of the load between 0°F and 35°F, and the unit running on backup alone was rare even above 0°F. If a heat pump goes in here, this is the kind it should be, not the standard model the cost figures above are built on.