What the cold actually does here
Winters here are long and they run cold. The heat is on ten months a year, September through June, and the overnight low averages 15°F across December, January and February. More than half the nights the heat runs, about 180 of them, drop to freezing or below. About 18 nights a year hit 0°F or colder.
A standard heat pump starts losing ground before any of that. Its heat output falls short of its rating once it's below 40°F outside, and it often needs backup heat below about 35°F. Fifteen degrees is under both marks, and so is every single one of those 180 freezing nights. That's not a cold-snap problem. That's most of the winter.
An ENERGY STAR cold-climate heat pump is built for exactly this. To earn that label it has to make at least 1.75 units of heat per unit of electricity at 5°F, and hold onto 70 percent of its 47°F capacity at that same temperature, checked by outside testing. A two-winter field test of prototype cold-climate units backed this up in practice: backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. If a heat pump is on the table here, this is the version that has a real case. A standard one does not.