What winter here does to a heat pump
Blaine County winters are the whole question. The heat runs ten months a year here, September through June, and the overnight low averages 10°F across December, January and February. That number sits well below both marks that matter for a heat pump: its output falls short of the rating once it's under 40°F outside, and below about 35°F it typically needs backup heat to keep up. An average winter night here is below both.
This isn't a handful of cold snaps. About 195 nights a year drop to freezing or below, better than half of the nights the heat runs. On every one of those nights, a standard heat pump is working below its rated capacity. About 30 nights a year reach 0°F or colder, and down there a heat pump is putting out only a fraction of what it's rated for, leaning hard on backup heat to make up the difference.
A cold-climate heat pump changes that math some. To earn the ENERGY STAR Cold Climate label, it has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, verified by outside testing, not the maker's own numbers. Field testing on prototype cold-climate units backs this up: backup heat covered only a small share of the heating load between 0°F and 35°F, and running on backup alone was rare even above 0°F. If a heat pump is on the table here, that's the kind to ask about. A standard one, built to the federal minimum, is not built for this county.