An outdoor heat pump unit mounted on a concrete pad in front of a two-story suburban house.

Heat Pump Repair in Wolf Point, MT

Tell us about the job

Takes about a minute. No obligation.

RepairHeat PumpRoosevelt County, MT
Step 1 of 2

What ZIP code is the job in?

Cold nights push it hard

Winter nights here average 5°F. A heat pump has to pull heat out of air that cold, and it runs long hours doing it. That kind of load wears on the parts that keep it running, the reversing valve, the defrost control, the compressor.

Storms add their own wear

Roosevelt County has seen damaging wind 127 times between 2015 and 2024, plus dozens of hail events and winter storms in that same stretch. An outdoor unit sitting through all that takes hits a system in a calmer spot never does, on top of the strain from the cold.

9 months
September through May, your system heats
2 months
July through August, it cools
5°F
the average winter night it heats against
81°F
the average summer afternoon it cools against
Isometric illustration of a cutaway single-family house showing interior ductwork and an air handler, with an outdoor condenser unit connected by lines along the exterior wall.
Your system heats September through May and cools July through August.

NOAA nClimDiv, 1991–2020 normals

A heat pump usually fails at the reversing valve or the defrost control, not the compressor.

The compressor is built to outlast the rest of the system, so look at the reversing valve and defrost control before worrying about it.

Power here runs 12.66 cents a kWh, so get the valve or control checked instead of letting it run rough

Power costs 12.66 cents a kWh statewide
Climate zone 6B
Cooling runs July through August
Nine months of heat, starting in SeptemberHeat pumps in Roosevelt County run from September through May, with August the month to get one checked.

Montana homes paid 12.66 cents per kilowatt-hour in 2024. That's not the cheapest power in the country, and a heat pump pulling long hours against a Wolf Point winter runs on that rate every day it's working. A stuck reversing valve or a defrost control that won't cycle right doesn't just leave you cold. It can mean the system runs constantly trying to catch up, and every hour of that shows up on the bill. A unit running rough for weeks before anyone looks at it costs more than the repair would have.

Find out what's actually wrong before it runs rough all winter

A system working this hard, through winters this cold and weather this rough, doesn't fail for no reason. If your heat pump is acting up, there's a real cause behind it, likely the reversing valve or the defrost control. Get it looked at before it runs rough any longer.

Find a contractor
A gray outdoor HVAC unit mounted on a concrete pad beside a house with gray lap siding and a stone foundation.

What you can check before anyone comes out

Check the outdoor unit first. Ice coating the coil is normal in small amounts, but if it's caked in frost or solid ice, something isn't defrosting right. Look at the fan. It should spin freely with nothing blocking it, no leaves, no ice, no snow piled against it. Inside, check your thermostat is actually set to heat and the temperature you expect. Change the air filter if you haven't in a while, a clogged one starves the system of airflow and can make it struggle no matter what else is wrong. Walk around to the vents and feel whether air is moving at all, and whether it feels colder than it should. If the system is running constantly and never reaching the temperature you set, or it's blowing air that feels cold when it should feel warm, those are signs worth noting before the call, not things to fix yourself. Don't take panels off the outdoor unit or touch the electrical disconnect. That part of the job belongs to someone trained for it.

It won't switch over

A heat pump stuck in one mode, blowing cold air when it should be warm, or not responding when you change the thermostat from heat to cool, usually means the reversing valve isn't shifting. Sometimes you'll hear it try, a clunk or a shudder from the outdoor unit, and then nothing changes. That's worth a call, not a wait.

It runs and runs without catching up

A heat pump that never shuts off, or short cycles on and off every few minutes, is telling you something underneath isn't working right. Long runtimes with no real change in indoor temperature, or a system that stops and starts constantly, both point to a problem that gets worse the longer it's ignored.

A reversing valve stuck halfway doesn't always shut the system down. It keeps running, pulling in power and moving air, just not fixing the temperature. A defrost control that won't cycle right works the same way, the outdoor coil ices over a little more each round, airflow drops, and the compressor has to work harder to move the same amount of heat. None of that fixes itself by running longer. Ice on a coil spreads. A compressor leaning on a bad valve is doing work it wasn't built to do that way, and the parts around it wear faster for it. The longer a system runs in that state, the more of its other parts get dragged into the failure.

Repair makes sense when the problem is one part acting up in a system that's otherwise sound, a reversing valve that's stuck, a defrost control that's lost its timing, a sensor giving bad readings. Those are known failures with known fixes, and fixing them brings the whole system back to normal. Replacement starts to make more sense when the compressor itself is the problem. It's built to outlast everything else in the system, so when it's failing, it usually means the system has been under strain for a long time, maybe from one of those smaller parts going bad long before anyone caught it. A tech can tell you which case you're in by checking pressures and watching how the system responds when it cycles, not by guessing from the symptoms alone. If a system has needed repeated repairs over a short stretch, that pattern matters as much as what's wrong this time.