Electricity here runs 14.07 cents a kilowatt-hour
A heat pump runs on electricity for both heating and cooling, so that rate applies every time it cycles on. Deer Lodge County homes pay that rate year round, not just in the months it's hot or cold.
Takes about a minute. No obligation.
A heat pump runs on electricity for both heating and cooling, so that rate applies every time it cycles on. Deer Lodge County homes pay that rate year round, not just in the months it's hot or cold.
An installer sizing this system for your house decides how hard it has to work to keep up. A unit that's undersized or oversized for your home runs more than it needs to, and at this rate that difference is worth catching before it's installed, not after.

Half the homes in Deer Lodge County were built in 1954 or earlier.
A heat pump going into a house that old has to be sized for the house, not just the square footage on paper.




Deer Lodge County falls in climate zone 6B, a cold zone with a long heating season. Any split-system heat pump installed here has to meet the federal minimum for that climate: at least 7.5 Btu of heat delivered for every watt-hour it uses over the winter, and at least 14.3 Btu of cooling for every watt-hour over the summer. That standard applies to equipment made from 2023 on, so it's already built into what's available to install. It doesn't pick the unit for your house. It sets the floor everything on the market has to clear before an installer even starts sizing it to your home.
Electricity here runs the same rate year round, and a heat pump answers to it every time it cycles on. That makes sizing the one decision worth getting right before the unit goes in, not after. A contractor working out the load for your house, not just the square footage, is what keeps this system from working harder than it has to.
Find a contractorA heat pump runs on both the hot days and the cold ones, so it logs more hours over a year than a furnace or an air conditioner alone would, each only carrying half the load. That's worth asking about directly when you compare systems. Ask how the compressor is rated to hold up over years of running in both directions, and what's covered if it fails outside the labor warranty, since it's the most expensive part in the cabinet. Ask how the unit performs at low outdoor temperatures too. That's when a heat pump has to work hardest to pull heat out of cold air, and some systems lean on backup heat strips more than others to get there. The answer tells you how much of the winter you're running efficient compressor heat versus expensive resistance heat, which is a different question from whether the unit is sized right for the house.
The efficiency rating on a heat pump's label is a ratio, not a guarantee. It compares the heat or cooling the unit delivers against the electricity it draws to do it. A higher number means more output for the same input, but that number comes from lab testing under set conditions. Your ductwork, your home's insulation, and how the unit gets installed all affect whether you see that rating play out in real use.
A heat pump carries separate ratings for heating and cooling, since it does both jobs through the same compressor and refrigerant line. A unit can be strong in one mode and average in the other. When you're comparing models, look at both numbers against what this system will actually be asked to do most, not just whichever rating looks best on the sticker.
Sizing a heat pump means working out how much heat the house loses on the coldest day and how much heat it gains on the hottest one, then matching a unit to that load. It's called a Manual J calculation, and it accounts for wall and ceiling insulation, window area, air leakage, and duct losses, not just the square footage inside the walls. Too big and the unit short cycles, reaching the thermostat setting fast and shutting off before it's pulled moisture out of the air or run long enough to settle into steady operation. Too small and it runs constantly on the worst days, leaning on backup heat strips to make up the difference and never quite catching up. Either mistake wears on the compressor, since it's cycling more often or straining longer than it should. A contractor who sizes it against the actual load, room by room, is giving the compressor a job it can do efficiently for the life of the system.
Installation day starts before anyone touches the old equipment. A contractor walks the house first, checking where the indoor air handler sits, where the outdoor unit will go, and what the existing ductwork or electrical panel can handle. Pulling the old system out comes next, and if the ducts need sealing or modifying to work with the new unit, that happens before anything gets set in place. The outdoor unit gets leveled on its pad, the indoor coil gets connected, and the refrigerant lines run between them get brazed and pressure tested for leaks before any refrigerant goes in. Once the system is charged to the manufacturer's spec, the contractor runs it through both modes, heating and cooling, checking airflow at the vents and making sure the thermostat is talking to the unit the way it should. A heat pump that's wired but never tested in both directions is still an unfinished job, not a finished one.