Winters here are too cold for a heat pump to carry alone
Your furnace here is doing a different job than it would in most places. Heat runs ten months a year in Toole County, September through June, and the overnight low averages 10°F through December, January and February. That is the number a heat pump has to answer for.
A standard heat pump starts losing ground below 40°F. Its heating output drops under its rating, and somewhere around 35°F it usually needs backup heat to make up the difference. Toole County sits below both marks almost every night of the heating season. Of the roughly 190 nights a year here at or below freezing, every one of them is cold enough to put a standard heat pump below both lines. About 30 nights a year drop to 0°F or lower, deep into the range where a standard heat pump is putting out only a fraction of what it's rated for.
That doesn't rule out a heat pump. It rules out a standard one. A model built and tested to the ENERGY STAR Cold Climate spec has to produce at least 1.75 units of heat per unit of electricity at 5°F, and hold onto 70 percent of its warm-weather capacity at that temperature, checked by an outside lab. A two-winter study of prototype cold-climate heat pumps in real homes backs that up: backup heat only carried a small share of the load between 0°F and 35°F, and the backup alone rarely ran things above 0°F. So the question for this county is not heat pump or furnace in the abstract. It's whether the heat pump in front of you is a cold climate model, because a standard one will spend the winter leaning on backup heat it probably doesn't have.