Why winter here decides this
Your heat runs ten months a year in Lincoln County, September through June, and the overnight low averages 19°F across December, January and February. That's below the point where a standard heat pump starts to struggle. Below 40°F a standard heat pump puts out less than its rated capacity. Below about 35°F it often needs backup heat to keep up. An average winter night here is under both marks.
This isn't a handful of cold snaps. About 175 nights a year here drop to freezing or below, more than half the nights the heat is on, and 19°F is colder than freezing. A heat pump sized for this house has to do its hardest work on most of the nights it runs.
A gas furnace doesn't have that problem. It burns gas to make heat, so outdoor temperature doesn't touch its output. It makes the same heat at 19°F as it does at 40°F.
Cold climate heat pumps close part of this gap. To earn that label a unit has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold on to 70 percent of its warmer-weather capacity at that temperature, checked by independent testing. A field test of prototype cold climate units over two winters found backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. That's a different machine than the standard heat pump priced in the running cost comparison above, and it matters here: this county only sees 0°F or below about 5 nights a year, so most of its cold is exactly the range where a cold climate unit is built to hold up.