What the cold here does to a heat pump
Winters in Powell County are long and hard. Heat runs eleven months a year, August through June, and the overnight low averages 14°F through December, January and February. About 220 nights a year drop to freezing or below. About 20 of those nights hit 0°F or colder.
A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says, and below about 35°F it usually needs backup heat to make up the difference. Here, the average winter night is already below both marks. Every single one of those 220 freezing nights is below both marks too. This is not a system that sees occasional stress. It would be working below its rated output most of the winter.
There is a version built for this. A heat pump with the ENERGY STAR Cold Climate rating has to prove it still makes at least 1.75 units of heat per unit of electricity at 5°F, and hold onto 70 percent of its 47°F capacity at that same temperature, checked by outside testing. Field tests of prototype cold-climate heat pumps back this up in practice: over two winters in occupied homes, backup heat covered only a small share of the load between 0°F and 35°F, and the system running on backup heat alone was rare even above 0°F. That is the difference between a heat pump that struggles here and one that was built for exactly this kind of winter. A standard model was not.