What the cold here does to a heat pump
Heat runs ten months a year here, September through June. The average overnight low in December, January and February is 14°F. A standard heat pump already falls short of its rated output once it's below 40°F outside, and below about 35°F it usually needs backup heat to keep up. Your average winter night is colder than both of those marks, and so is every one of the roughly 175 nights a year here that drop to freezing or below.
That doesn't mean a heat pump can't do the job. Models built for cold climates are tested down to 5°F and have to hold onto most of their rated capacity at that temperature. Field tests of these units found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. But the $1.69 figure on this page is for a heat pump built to the federal minimum, not one of these cold climate models, and it adds nothing for backup heat. On one of the roughly 25 nights a year here that reach 0°F, a standard heat pump is leaning hard on backup, and that cost is not in the $1.69.